FEATURES 160 X 80 Monochrome Graphic Display for Comprehensive Process Information4 Sensor for temperature mappingone sensor for controllingDigital Inputs for Door Open Low Water Level DetectionDigital Outputs SSR Drive for Heating Air Exhaust Valve and AlarmProgrammable Sterilization Timer with Setpoints for Timer Pause ResetProgrammable Setpoint for Air Exhaust Valve ClosingAutomatic Cycle Abortion at High Temperature Safety Limit Low Water LevelF0 Value Calculation IndicationProgrammable CycleEnd Strategy 1 Immediate upon End of Sterilization Time2 After Preset Temperature Drop from End of Sterilization3 After Preset Time Elapse from End of SterilizationInbuilt Huge Memory for Autoclave Cycle Data Recording with Settable IntervalLid locked under pressureShort circuit breaker over Load protection SPECIFICATIONSOperating Temperature rangeSterilizing 121 CWarming 4595 CPurging Upto 99 CMaximum Operating Pressure 15 PSITemperature Display DigitalPressure Display AnalogueAnalog Pressure Gauge Max value 35 PSIHeat Source Load 45 KWSafety Devices Water Level Sensor LID Interlock Over temperature protection Over Pressure Protection Pressure Safety ValveTime Display DigitalTime Range 0 to 999 MinsChamber Dimension Dia mm x Depth mm 500 x 917Chamber Busket Dimension 475 x 800Capacity 180 LtrsOuter body dimension W x D x H mm 680 X 720 X 1352Outer body material GI sheet powder coatedInner body material SS 304 sheetGross weight 180 kgsVoltage 220 vaEnvironmental Conditions Ambient temperature 15 to 45 deg CelAmbient Pressure AtmosphericRelative Humidity 30 to 70 OPTIONAL SPECIFICATIONS Operating temperature range for sterilization 135 deg CMaximum operating pressure 30 PSIOuter body material SS 304 sheet Accessories AMBI VAV PRAC4 21 CFR complainse PC softwareAMBI VAV PRAC5 Dot matrix printerAMBI VAV AC1 Stainless steel wiremesh busketAMBI VAV AC2 Stainless steel perforated sheet busket
FAQs of AUTOCLAVE (PRIME SERIES) Model: AMBI-VAV-1800PRK:
Q: What is the sterilizing temperature of the AUTOCLAVE (PRIME SERIES) Model AMBI-VAV-1800PRK?
A: The sterilizing temperature of this autoclave is 121C.
Q: What is the operating method for the AUTOCLAVE (PRIME SERIES) Model AMBI-VAV-1800PRK?
A: The operating method for this autoclave is manual.
Q: What material is used to construct the AUTOCLAVE (PRIME SERIES) Model AMBI-VAV-1800PRK?
A: The autoclave is constructed using MS (Mild Steel).
Q: What is the working pressure of the AUTOCLAVE (PRIME SERIES) Model AMBI-VAV-1800PRK?
A: The working pressure of this autoclave is 15 PSI.
Q: What voltage range does the AUTOCLAVE (PRIME SERIES) Model AMBI-VAV-1800PRK operate on?
A: The autoclave operates within a voltage range of 110-215 Volt (V).
Tell us about your requirement
Price: Â
Quantity
Select Unit
50
100
200
250
500
1000+
Additional detail
मोबाइल number
Email
Name
Comapny Name
फ़ोन Number
Email Id
City / State
Confirm Your Requirement
Verification Code
Did not receive yet?
Resend OTP
Youâre Done!
We have received your requirements and will reply shortly with the best price.